logged_at,capture_ts,capture_num,claude_said_flicker,user_confirmed,lp_low_ns,reasoning_summary
2026-04-16 07:59:52,20260416_075857,0031,YES,NO,0.3,YES The LP-low plateau measured at 0.3 ns is effectively absent — nearly three orders of magnitude below the SN65DSI83's required ≥ 50 ns minimum for
2026-04-16 08:10:15,20260416_080919,0006,YES,NO,0.3,"YES The LP-low plateau measured at 0.3 ns is essentially absent, far below the 50 ns minimum required by the SN65DSI83 to detect the start-of-transmi"
2026-04-16 08:13:26,20260416_081232,0013,YES,YES,0.3,"YES The LP-low plateau is measured at effectively 0 ns (0.3 ns reported, rounded to 0 ns in the summary), which is drastically below the SN65DSI83's "
2026-04-16 08:20:46,20260416_082018,0001,NO,NOT_ASKED,108.0,"NO The LP-low plateau measures 108.0 ns, which comfortably exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection. This is the critical "
2026-04-16 08:21:16,20260416_082047,0002,NO,NOT_ASKED,108.3,"NO The LP-low plateau measures 108.3 ns, which comfortably exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection. The flagged concern a"
2026-04-16 08:21:46,20260416_082117,0003,NO,NOT_ASKED,342.7,"NO The LP-low plateau measures 342.7 ns, which is well above the 50 ns minimum required by the SN65DSI83 for SoT detection. The flag appears to be a "
2026-04-16 08:22:14,20260416_082147,0004,NO,NOT_ASKED,342.7,"NO The LP-low plateau measures 342.7 ns, which comfortably exceeds the 50 ns minimum required by the SN65DSI83 for SoT detection. The flag appears to"
2026-04-16 08:30:29,20260416_082936,0005,YES,NO,0.3,"YES The LP-low plateau measured at effectively 0 ns (reported as 0.3 ns by the flag, 0 ns in the full summary) is drastically below the 50 ns minimum"
2026-04-16 08:32:52,20260416_083201,0010,YES,NO,0.3,"YES The LP-low plateau measured only 0.3 ns, which is effectively absent and far below the SN65DSI83's required ≥ 50 ns minimum for reliable SoT dete"
2026-04-16 08:41:32,20260416_084055,0009,YES,YES,0.2,"YES The LP-low plateau is measured at effectively 0 ns (reported as 0.2 ns by the pre-processor, 0 ns in the full summary), far below the 50 ns minim"
2026-04-16 09:17:52,20260416_091714,0002,YES,NO,0.3,YES The LP-low plateau measured at effectively 0 ns (reported 0.3 ns) is drastically below the SN65DSI83's required ≥ 50 ns minimum for SoT detection
2026-04-16 09:28:27,20260416_092745,0029,YES,NO,0.3,YES The LP-low plateau of 0.3 ns is essentially absent—two orders of magnitude below the SN65DSI83's required ≥ 50 ns minimum for SoT detection. The
2026-04-16 09:33:17,20260416_093239,0041,YES,NO,0.3,"YES The LP-low plateau is measured at effectively 0 ns (flagged as 0.3 ns by the pre-processor), far below the SN65DSI83's 50 ns minimum requirement "
2026-04-16 09:37:46,20260416_093705,0052,YES,NO,0.3,YES The LP-low plateau measured at 0.3 ns is effectively absent — it is over two orders of magnitude below the SN65DSI83's required ≥ 50 ns minimum f
2026-04-16 09:52:50,20260416_095213,0091,YES,NO,0.2,YES The LP-low plateau measured at 0.2 ns is essentially absent — nearly three orders of magnitude below the SN65DSI83's required ≥ 50 ns minimum for
2026-04-16 09:53:48,20260416_095313,0093,YES,NO,0.2,YES The LP-low plateau measured at effectively 0 ns (reported 0.2 ns) is vastly below the 50 ns minimum required by the SN65DSI83 to detect the Start
2026-04-16 09:54:48,20260416_095412,0095,YES,NO,0.3,"YES The LP-low plateau is measured at effectively 0 ns (reported as 0.3 ns by the flag, 0 ns in the full summary), which is drastically below the SN6"
2026-04-16 09:58:51,20260416_095814,0105,YES,NO,0.9,"YES The LP-low plateau measured at only ~1 ns, which is drastically below the SN65DSI83's required ≥50 ns minimum for reliable SoT detection — fallin"
2026-04-16 10:06:18,20260416_100542,0124,YES,NO,0.3,"YES The LP-low plateau measured at effectively 0 ns (reported as 0.3 ns by the pre-processor, 0 ns in the full summary) is drastically below the 50 n"
2026-04-16 10:10:44,20260416_101007,0135,YES,NO,23.1,"YES The LP-low plateau of 23.1 ns is less than half the SN65DSI83's required ≥ 50 ns minimum for reliable SoT detection, and the LP exit-to-HS transi"
2026-04-16 10:12:30,20260416_101154,0139,YES,NO,0.2,"YES The LP-low plateau is measured at effectively 0 ns (reported as 0.2 ns by the flag, 0 ns in the full summary), far below the 50 ns minimum requir"
2026-04-16 10:14:38,20260416_101402,0144,YES,NO,0.2,"YES The LP-low plateau is measured at effectively 0 ns (reported as 0.2 ns by the pre-processor, 0 ns in the full summary), far below the SN65DSI83's"
2026-04-16 10:15:16,20260416_101439,0145,YES,NO,0.2,"YES The LP-low plateau is effectively absent at 0.2 ns (rounded to 0 ns in the full summary), which is drastically below the SN65DSI83's required ≥ 5"
2026-04-16 10:21:14,20260416_102036,0160,YES,NO,39.8,"YES The LP-low plateau of 39.8 ns is clearly below the SN65DSI83's required ≥ 50 ns minimum for reliable SoT detection, falling short by over 10 ns ("
2026-04-16 10:25:18,20260416_102440,0170,YES,NO,0.3,YES The LP-low plateau measured at 0.3 ns is effectively absent and falls catastrophically short of the SN65DSI83's required ≥ 50 ns minimum for SoT
2026-04-16 10:27:54,20260416_102713,0176,YES,NO,0.9,YES The LP-low plateau measured at only 0.9 ns is drastically below the SN65DSI83's required ≥ 50 ns minimum for SoT detection — it is essentially ab
2026-04-16 11:12:48,20260416_111206,0065,YES,NO,26.7,"YES The LP-low plateau of 26.7 ns is barely half the SN65DSI83's required ≥ 50 ns minimum, and the LP exit-to-HS transition of only 4 ns is drastical"
2026-04-16 11:24:30,20260416_112353,0001,YES,NO,342.7,"YES Although the LP-low plateau itself is 343 ns (well above the 50 ns minimum), the critical failure here is the **LP exit → HS transition of only 3"
2026-04-16 11:25:07,20260416_112431,0002,YES,NO,342.6,"YES The LP-low plateau at 343 ns is well above the 50 ns SN65DSI83 detection threshold, so the SoT preamble timing itself is not the problem here. Ho"
2026-04-16 11:26:06,20260416_112531,0004,YES,NO,342.6,"YES Although the LP-low plateau itself is 343 ns (well above the 50 ns minimum), the critical failure here is the HS amplitude of only 17 mV, far bel"
2026-04-16 11:27:06,20260416_112630,0006,YES,NO,108.0,"YES Although the LP-low plateau itself measures 108 ns (above the 50 ns minimum), the critical failure here is the **LP exit → HS transition of only "
2026-04-16 12:09:44,20260416_120916,0002,NO,NOT_ASKED,342.7,NO The LP-low plateau of 342.7 ns and the LP-11-to-HS transition time of 347.7 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement f
2026-04-16 12:16:16,20260416_121548,0019,NO,NOT_ASKED,342.3,NO The LP-low plateau of 342.3 ns and LP-11→HS transition time of 347.5 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement for SoT
2026-04-16 12:46:09,20260416_123835,0079,YES,NO,49.6,"YES The LP-low plateau measured at 49.650 ns is right at the absolute edge of the SN65DSI83's 50 ns minimum detection threshold, and the pre-process"
2026-04-16 12:48:09,20260416_124741,0084,NO,NOT_ASKED,108.1,"NO The LP-low plateau of 108.1 ns and the LP-11-to-HS transition time of 113.2 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement, "
2026-04-16 12:58:17,20260416_125738,0110,YES,NO,46.6,"YES The LP-low plateau of 46.647 ns is below the SN65DSI83's required ≥ 50 ns minimum for reliable SoT detection, falling short by approximately 33"
2026-04-16 13:01:50,20260416_130120,0119,NO,NOT_ASKED,342.6,"NO The LP-low plateau of 342.6 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP→HS transition timing of 347.8 n"
2026-04-16 13:02:22,20260416_130151,0120,NO,NOT_ASKED,108.2,"NO The LP-low plateau of 108.2 ns and the LP-11→HS transition time of 113.3 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement, so "
2026-04-16 13:08:35,20260416_130807,0136,NO,NOT_ASKED,342.7,"NO The LP-low plateau of 342.7 ns and the LP-11-to-HS transition time of 347.8 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement, "
2026-04-16 13:17:22,20260416_131640,0158,YES,NO,27.2,"YES The LP-low plateau of 27.2 ns is well below the SN65DSI83's required 50 ns minimum for reliable SoT detection. Additionally, the LP exit-to-HS tr"
2026-04-16 13:19:47,20260416_131918,0164,NO,NOT_ASKED,342.4,NO The LP-low plateau of 342.4 ns and LP-11→HS transition time of 347.8 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement for SoT
2026-04-16 13:22:12,20260416_132143,0170,NO,NOT_ASKED,108.0,"NO The LP-low plateau of 108.0 ns comfortably exceeds the SN65DSI83's 50 ns minimum requirement, and the LP-11 voltage (1.016 V) and LP-exit-to-HS ti"
2026-04-16 13:23:07,20260416_132237,0172,NO,NOT_ASKED,342.6,"NO The LP-low plateau of 342.6 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP→HS transition timing of 348 ns "
2026-04-16 13:30:31,20260416_133001,0191,NO,NOT_ASKED,342.4,NO The LP-low plateau of 342.4 ns and the LP-11-to-HS transition time of 347.6 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement f
2026-04-16 13:36:31,20260416_133554,0206,YES,NO,44.6,"YES The LP-low plateau of 44.6 ns is below the SN65DSI83's required ≥ 50 ns minimum for reliable SoT detection, and the LP exit-to-HS transition time"
2026-04-16 13:57:51,20260416_135714,0261,YES,NO,49.3,"YES The LP-low plateau of 49.3 ns is below the SN65DSI83's required 50 ns minimum for reliable SoT detection, and the LP exit-to-HS transition of onl"
2026-04-16 14:02:58,20260416_140229,0274,NO,NOT_ASKED,342.7,NO The LP-low plateau of 342.7 ns and the LP-11-to-HS transition time of 347.8 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement f
2026-04-16 14:05:00,20260416_140431,0279,NO,NOT_ASKED,107.8,"NO The LP-low plateau measures 107.8 ns, which comfortably exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 voltage"
2026-04-16 14:05:29,20260416_140501,0280,NO,NOT_ASKED,342.8,NO The LP-low plateau of 342.8 ns and the LP-11→HS transition time of 347.9 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement for
2026-04-16 14:06:00,20260416_140531,0281,NO,NOT_ASKED,342.6,"NO The LP-low plateau of 342.6 ns and the LP-11→HS transition time of 347.5 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement, so "
2026-04-16 14:10:54,20260416_141016,0293,YES,NO,25.6,YES The LP-low plateau of 25.626 ns is roughly half the 50 ns minimum required by the SN65DSI83 to reliably detect the Start-of-Transmission sequenc
2026-04-16 14:17:09,20260416_141640,0309,NO,NOT_ASKED,342.8,NO The LP-low plateau of 342.8 ns and the LP-11→HS transition time of 347.6 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement for
2026-04-16 14:22:13,20260416_142146,0322,NO,NOT_ASKED,342.7,"NO The LP-low plateau of 342.7 ns and the LP-11-to-HS transition time of 347.8 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement, "
2026-04-16 15:36:49,20260416_142759,0338,YES,NO,,"YES The LP-low plateau is reported as `None` (absent), meaning the DAT0 lane never presented a valid LP-01/LP-00 preamble long enough to be measured "
2026-04-17 08:45:23,20260417_084455,0001,NO,NOT_ASKED,107.8,"NO The LP-low plateau measures 107.8 ns, which comfortably exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection. The LP-11 voltage (1."
2026-04-17 08:47:03,20260417_084634,0005,NO,NOT_ASKED,53.2,"NO The LP-low plateau measures 53.2 ns, which exceeds the SN65DSI83's 50 ns minimum detection threshold, so the SoT preamble timing itself is valid a"
2026-04-17 08:54:05,20260417_085336,0023,NO,NOT_ASKED,342.4,"NO The LP-low plateau of 342.4 ns and the LP-11-to-HS transition time of 347.7 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement, "
2026-04-17 08:56:31,20260417_085602,0029,NO,NOT_ASKED,342.6,NO The LP-low plateau of 342.6 ns and the LP-11-to-HS transition time of 347.8 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement f
2026-04-17 08:58:12,20260417_085742,0033,NO,NOT_ASKED,342.5,NO The LP-low plateau of 342.5 ns and LP-11→HS transition time of 347.5 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement for SoT
2026-04-17 09:16:09,20260417_091529,0079,YES,NO,12.2,"YES The LP-low plateau of 12.2 ns is far below the SN65DSI83's required ≥ 50 ns minimum for reliable SoT detection, at only ~24% of the threshold. Th"
2026-04-17 09:17:37,20260417_091657,0082,YES,NO,6.8,YES The LP-low plateau of 6.8 ns is dramatically below the SN65DSI83's 50 ns minimum requirement for SoT detection — it is only ~14% of the needed du
2026-04-17 09:18:54,20260417_091825,0085,NO,NOT_ASKED,342.5,NO The LP-low plateau of 342.5 ns and the LP-exit-to-HS transition time of 348 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement f
2026-04-17 09:41:09,20260417_094040,0002,NO,NOT_ASKED,379.5,"NO The LP-low plateau measures 379.5 ns, which comfortably exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the full LP→HS en"
2026-04-17 09:50:37,20260417_095000,0026,YES,NO,33.0,"YES The LP-low plateau of 33 ns is well below the SN65DSI83's required 50 ns minimum for reliable SoT detection, and the LP exit-to-HS transition of "
2026-04-17 09:56:13,20260417_095538,0040,NO,NOT_ASKED,379.7,NO The LP-low plateau of 379.7 ns and LP-11→HS transition time of 384.8 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement for SoT
2026-04-17 10:00:43,20260417_100005,0051,YES,NO,27.0,"YES The LP-low plateau of 27 ns is well below the SN65DSI83's required ≥ 50 ns minimum for reliable SoT detection, and the LP exit-to-HS transition t"
2026-04-17 10:01:20,20260417_100044,0052,YES,NO,25.7,"YES The LP-low plateau measured at 25.726 ns is roughly half the SN65DSI83's required ≥ 50 ns minimum, meaning the bridge almost certainly failed to"
2026-04-17 10:01:58,20260417_100121,0053,YES,NO,46.4,"YES The LP-low plateau of 46.4 ns is below the SN65DSI83's required 50 ns minimum for reliable SoT detection, and the LP exit-to-HS transition of onl"
2026-04-17 10:06:02,20260417_100527,0063,YES,NO,,"YES The LP-low plateau is reported as `None` (absent), and the LP exit → HS transition time is 0 ns—both far below the SN65DSI83's required ≥ 50 ns L"
2026-04-17 10:14:21,20260417_101343,0084,YES,NO,42.9,"YES The LP-low plateau of 42.9 ns is below the SN65DSI83's required 50 ns minimum for reliable SoT detection. Additionally, the LP exit-to-HS transit"
2026-04-17 10:15:46,20260417_101509,0087,YES,NO,34.1,"YES The LP-low plateau of 34.1 ns is well below the SN65DSI83's required ≥ 50 ns minimum for reliable SoT detection, falling short by nearly 16 ns (~"
2026-04-17 10:18:00,20260417_101718,0092,YES,NO,,"YES The LP-low plateau is completely absent (reported as `None` / 0 ns), far below the SN65DSI83's minimum 50 ns requirement for SoT detection. Addit"
2026-04-17 10:23:29,20260417_102300,0106,NO,NOT_ASKED,379.5,"NO The LP-low plateau of 379.5 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP→HS transition timing of 384.6 n"
2026-04-17 11:29:04,20260417_112836,0001,NO,NOT_ASKED,379.5,"NO The LP-low plateau of 379.5 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP→HS transition timing of 384.6 n"
2026-04-17 11:48:15,20260417_113037,0006,YES,NO,107.6,"YES The LP-low plateau at ~108 ns comfortably exceeds the 50 ns SN65DSI83 requirement, so that alone would not cause a missed SoT. However, the LP ex"
2026-04-17 11:53:37,20260417_114925,0010,YES,NO,6.9,"YES The LP-low plateau of 6.9 ns is dramatically below the SN65DSI83's 50 ns minimum detection threshold, and the LP exit-to-HS transition of only 1 "
2026-04-17 11:55:01,20260417_115424,0013,YES,NO,108.0,"YES The HS amplitude of 33 mV is critically low—well below the SN65DSI83's differential detection threshold (normal range 105122 mV), meaning the br"
2026-04-17 12:02:08,20260417_120132,0031,YES,NO,108.2,"YES The LP-low plateau of 108 ns meets the ≥50 ns requirement, but the LP exit→HS transition of only 3.4 ns is critically below the 50 ns minimum spe"
2026-04-17 12:06:13,20260417_120537,0041,YES,NO,12.9,"YES The LP-low plateau of 12.9 ns is dramatically below the SN65DSI83's required ≥ 50 ns minimum, giving the bridge only ~26% of the time it needs to"
2026-04-17 12:07:05,20260417_120637,0043,NO,NOT_ASKED,107.9,"NO The LP-low plateau measures 107.9 ns, which comfortably exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection. The LP-11 voltage (1."
2026-04-17 12:11:25,20260417_121057,0054,NO,NOT_ASKED,379.6,"NO The LP-low plateau of 379.6 ns and the LP-11-to-HS transition time of 384.8 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement, "
2026-04-17 12:13:17,20260417_121236,0058,YES,NO,107.6,"YES The HS amplitude of 31 mV is critically low — well below the SN65DSI83's differential receiver threshold (normal range 105122 mV, and flagged ab"
2026-04-17 12:13:52,20260417_121318,0059,YES,NO,108.0,"YES The LP-low plateau of 108 ns meets the ≥50 ns requirement, but the LP exit → HS transition of only 3 ns is critically below the 50 ns minimum spe"
2026-04-17 12:15:08,20260417_121439,0062,NO,NOT_ASKED,379.6,"NO The LP-low plateau of 379.6 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 voltage of 1.017 V is within"
2026-04-17 12:16:31,20260417_121555,0065,YES,NO,107.8,YES The HS amplitude of only 24 mV (single-ended) is critically below the normal 105122 mV range and well under the 50 mV threshold for a valid HS s
2026-04-17 12:19:18,20260417_121850,0072,NO,NOT_ASKED,379.6,"NO The LP-low plateau of 379.6 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 voltage of 1.016 V is within"
2026-04-17 12:25:15,20260417_122200,0080,YES,NO,22.0,"YES The LP-low plateau of 22 ns is less than half the SN65DSI83's required ≥ 50 ns minimum for reliable SoT detection, and the LP exit-to-HS transiti"
2026-04-17 12:49:33,20260417_122821,0089,YES,NO,,"YES The LP-low plateau is completely absent (reported as `None` / 0 ns), far below the SN65DSI83's 50 ns minimum requirement for SoT detection. Addit"
2026-04-17 12:50:57,20260417_125020,0092,YES,NO,107.8,"YES The HS amplitude of 23 mV is critically low — well below the SN65DSI83's differential detection threshold (normal range 105122 mV, and flagged a"
2026-04-17 12:52:22,20260417_125144,0095,YES,NO,107.8,"YES The HS amplitude of 28 mV is critically low—well below the SN65DSI83's differential detection threshold (normal range 105122 mV, and flagged abs"
2026-04-17 12:52:51,20260417_125223,0096,NO,NOT_ASKED,108.0,"NO The LP-low plateau measures 108.0 ns, which comfortably exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 voltage"
2026-04-17 12:53:54,20260417_125316,0098,YES,NO,107.6,"YES The HS amplitude of only 24 mV (single-ended) is critically below the normal 105122 mV range and well under the 50 mV ""absent"" threshold, indica"
2026-04-17 12:55:18,20260417_125442,0101,YES,NO,108.0,"YES The LP-low plateau itself at 108 ns is adequate (≥ 50 ns), but the LP exit-to-HS transition of only 3 ns is critically below the 50 ns minimum sp"
2026-04-17 12:56:40,20260417_125605,0104,YES,NO,107.7,"YES The critical issue here is the **LP exit → HS transition time of only 3 ns**, which is far below the 50 ns minimum required by the SN65DSI83. Whi"
2026-04-17 12:57:15,20260417_125642,0105,YES,NO,108.0,"YES The LP-low plateau of 108 ns is above the 50 ns threshold, but the LP exit → HS transition time of only 1 ns is critically below the 50 ns minimu"
2026-04-17 13:00:53,20260417_130019,0114,YES,NO,107.7,"YES The HS amplitude of 22 mV is critically below the normal 105122 mV range and well under the 50 mV ""absent"" threshold, indicating the HS data bur"
2026-04-17 13:03:00,20260417_130226,0119,YES,NO,107.8,"YES The HS amplitude of 28 mV is critically below the normal 105122 mV range and well under the 50 mV threshold, indicating the HS data burst was es"
2026-04-17 13:03:35,20260417_130301,0120,YES,NO,108.2,"YES The HS amplitude of only 26 mV (well below the normal 105122 mV range and under the 50 mV ""absent"" threshold) indicates the HS data burst was es"
2026-04-17 13:07:56,20260417_130727,0131,NO,NOT_ASKED,379.5,"NO The LP-low plateau of 379.5 ns vastly exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP→HS transition timing of 384."
2026-04-17 13:10:04,20260417_130928,0136,YES,NO,107.8,"YES The HS amplitude of only 26 mV is far below the normal 105122 mV range and falls under the 50 mV ""absent"" threshold, indicating the HS data burs"
2026-04-17 13:10:33,20260417_131006,0137,NO,NOT_ASKED,379.7,"NO The LP-low plateau of 379.7 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 voltage of 1.016 V is within"
2026-04-17 13:12:19,20260417_131144,0141,YES,NO,108.0,"YES The LP-low plateau of 108 ns meets the ≥50 ns requirement, but the LP exit → HS transition of only 3 ns is critically below the 50 ns minimum spe"
2026-04-17 13:13:18,20260417_131243,0143,YES,NO,107.6,"YES Although the LP-low plateau itself measures ~108 ns (well above the 50 ns minimum), the LP-exit-to-HS transition time of only 1.01.3 ns is criti"
2026-04-17 13:15:26,20260417_131452,0148,YES,NO,58.7,"YES Although the LP-low plateau itself measures 58.759 ns (above the 50 ns minimum), the LP exit → HS transition duration is only 1.72 ns, far belo"
2026-04-17 13:15:56,20260417_131527,0149,NO,NOT_ASKED,379.6,"NO The LP-low plateau of 379.6 ns vastly exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 voltage of 1.015 V is wit"
2026-04-17 13:17:42,20260417_131707,0153,YES,NO,107.6,"YES The HS amplitude of only 30 mV (single-ended) is far below the normal 105122 mV range and falls under the 50 mV ""absent"" threshold, indicating t"
2026-04-17 13:22:33,20260417_132157,0165,YES,NO,107.6,YES The HS amplitude of only 25 mV (single-ended) is critically below the normal 105122 mV range and well under any reasonable detection threshold (
2026-04-17 13:23:02,20260417_132234,0166,NO,NOT_ASKED,379.6,"NO The LP-low plateau of 379.6 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 voltage of 1.016 V is within"
2026-04-17 13:24:49,20260417_132412,0170,YES,NO,107.8,"YES The LP-low plateau itself measures 108 ns (≥ 50 ns), but the critical failure is the **LP exit → HS transition of only 4 ns**, far below the 50 n"
2026-04-17 13:31:57,20260417_133058,0187,YES,NO,108.0,"YES The LP-low plateau of 108 ns meets the ≥50 ns requirement, but the LP exit → HS transition of only 4 ns is critically below the 50 ns minimum spe"
2026-04-17 13:32:57,20260417_133222,0189,YES,NO,27.0,"YES The LP-low plateau of 27 ns is well below the SN65DSI83's required ≥ 50 ns minimum for reliable SoT detection, and the LP exit-to-HS transition o"
2026-04-17 13:33:52,20260417_133322,0191,NO,NOT_ASKED,193.7,"NO The LP-low plateau measures 193.7 ns, which comfortably exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, so the bridge should "
2026-04-17 13:34:51,20260417_133416,0193,YES,NO,108.2,YES The HS amplitude of only 24 mV (single-ended) is critically below the normal 105122 mV range and well under the 50 mV threshold for a valid HS s
2026-04-17 13:44:19,20260417_134343,0217,YES,NO,107.8,YES The HS amplitude of 30 mV is critically low—well below the normal 105122 mV range and under the 50 mV threshold that indicates an essentially ab
2026-04-17 13:47:59,20260417_134724,0226,YES,NO,107.6,"YES The HS amplitude of 29 mV is critically low — well below the SN65DSI83's differential detection threshold (normal range 105122 mV), meaning the "
2026-04-17 13:56:36,20260417_135604,0248,NO,NOT_ASKED,379.8,"NO The LP-low plateau of 379.8 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 voltage of 1.015 V is within"
2026-04-17 14:00:17,20260417_135942,0257,YES,NO,27.3,"YES The LP-low plateau of 27.3 ns is well below the SN65DSI83's required 50 ns minimum for reliable SoT detection, and the LP exit-to-HS transition o"
2026-04-17 14:03:14,20260417_140237,0264,YES,NO,108.2,"YES The HS amplitude of 30 mV is critically low—well below the SN65DSI83's differential detection threshold (normal range 105122 mV, and flagged abs"
2026-04-17 14:05:40,20260417_140510,0270,NO,NOT_ASKED,379.5,"NO The LP-low plateau of 379.5 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP→HS transition timing of 384.7 n"
2026-04-17 14:06:33,20260417_140604,0272,NO,NOT_ASKED,379.5,"NO The LP-low plateau of 379.5 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP→HS transition timing of 384.6 n"
2026-04-17 14:08:57,20260417_140829,0278,NO,NOT_ASKED,107.6,"NO The LP-low plateau measures 107.6108 ns, which comfortably exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 vol"
2026-04-17 14:09:57,20260417_140922,0280,YES,NO,,"YES The DAT0 LP-low plateau is reported as **None** (absent/undetectable), which falls critically below the SN65DSI83's minimum 50 ns requirement for"
2026-04-17 14:11:07,20260417_140958,0281,YES,NO,108.2,"YES The critical failure here is the **LP exit → HS transition of only 4 ns**, far below the 50 ns minimum required by the SN65DSI83. Although the LP"
2026-04-17 14:11:43,20260417_141108,0282,YES,NO,107.8,"YES The HS amplitude of 25 mV is critically below the normal 105122 mV range and well under the 50 mV threshold, indicating the HS data burst is ess"
2026-04-17 14:12:58,20260417_141207,0284,YES,NO,108.0,"YES The LP-low plateau of 108 ns meets the ≥50 ns requirement, but the LP exit → HS transition of only 3 ns is critically below the 50 ns minimum spe"
2026-04-17 14:16:55,20260417_141626,0294,NO,NOT_ASKED,108.0,"NO The LP-low plateau of 108.0 ns comfortably exceeds the SN65DSI83's 50 ns minimum requirement, and the LP-11 voltage (1.016 V) and LP exit-to-HS tr"
2026-04-17 14:17:25,20260417_141657,0295,NO,NOT_ASKED,379.5,"NO The LP-low plateau measures 379.5 ns, which far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the full LP→HS sequence ("
2026-04-17 14:18:04,20260417_141726,0296,YES,NO,107.8,YES The HS amplitude of 28 mV is critically low — well below the SN65DSI83's minimum differential detection threshold (typically ~70 mV single-ended
2026-04-17 14:19:43,20260417_141915,0300,NO,NOT_ASKED,379.6,"NO The LP-low plateau of 379.6 ns far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP-11 voltage of 1.015 V is within"
2026-04-17 14:22:09,20260417_142140,0306,NO,NOT_ASKED,379.2,NO The LP-low plateau of 379.2 ns and LP-11→HS transition time of 384.6 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement for SoT
2026-04-17 14:25:03,20260417_142428,0313,YES,NO,107.8,YES The HS amplitude of only 24 mV (single-ended) is critically below the normal 105122 mV range and well under the 50 mV threshold for a valid HS s
2026-04-17 14:27:04,20260417_142636,0318,NO,NOT_ASKED,379.5,"NO The LP-low plateau of 379.5 ns and the LP-11-to-HS transition time of 384.8 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement, "
2026-04-17 14:27:57,20260417_142728,0320,NO,NOT_ASKED,379.6,"NO The LP-low plateau is 379.6 ns, which far exceeds the SN65DSI83's 50 ns minimum requirement for SoT detection, and the LP→HS entry sequence is fla"
2026-04-17 14:28:50,20260417_142822,0322,NO,NOT_ASKED,379.3,NO The LP-low plateau of 379.3 ns and the LP-11-to-HS transition time of 384.8 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement f
2026-04-17 14:29:30,20260417_142851,0323,YES,NO,107.9,YES The HS amplitude of only 30 mV (single-ended) is critically below the normal 105122 mV range and well under the SN65DSI83's differential input t
2026-04-17 14:31:07,20260417_143017,0326,YES,NO,194.0,"YES The LP-low plateau of 194 ns is well above the 50 ns SN65DSI83 requirement, so by itself it should be sufficient for SoT detection. However, the "
2026-04-17 14:33:08,20260417_143240,0331,NO,NOT_ASKED,379.6,NO The LP-low plateau of 379.6 ns and the LP-11-to-HS transition time of 384.6 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement f
2026-04-17 14:36:30,20260417_143551,0339,YES,NO,108.0,"YES The LP-low plateau at 108 ns is above the 50 ns minimum, so that alone would be fine — but the LP exit → HS transition time of only 1 ns is criti"
2026-04-17 14:37:30,20260417_143654,0341,YES,NO,107.6,"YES The LP-low plateau itself at ~108 ns is adequate (≥ 50 ns), but the LP exit → HS transition time of only 3 ns is critically below the 50 ns minim"
2026-04-17 14:43:04,20260417_144230,0355,YES,NO,108.0,"YES The LP-low plateau of 108 ns meets the ≥50 ns requirement, but the LP exit-to-HS transition of only 2 ns is critically below the 50 ns spec minim"
2026-04-17 14:44:43,20260417_144415,0359,NO,NOT_ASKED,379.6,NO The LP-low plateau of 379.6 ns and the LP-11→HS transition time of 384.6 ns both comfortably exceed the SN65DSI83's 50 ns minimum requirement for
2026-04-17 14:48:47,20260417_144749,0368,YES,YES,107.8,YES The HS amplitude of 32 mV is critically low — well below the SN65DSI83's minimum differential detection threshold (typically ~70 mV single-ended