MIPI Interactive Flicker Test Report
Generated: 2026-04-16 08:41:33 |
Model: claude-opus-4-6
Stop reason: Flicker confirmed by operator at capture 0009 [20260416_084055]
1 confirmed flicker(s)
0 false alarm(s)
0 Claude said no
Event Log
| Capture | Timestamp | Channel |
LP-low plateau | LP exit→HS | LP-11 voltage |
Claude: flicker? | Outcome |
| 0009 | 20260416_084055 | dat | 0.2 ns | 3.5 ns | 1.016 V | YES | ✖ CONFIRMED FLICKER |
Claude Assessments
Capture 0009 [20260416_084055] — CONFIRMED FLICKER
YES
The LP-low plateau is measured at effectively 0 ns (reported as 0.2 ns by the pre-processor, 0 ns in the full summary), far below the 50 ns minimum required by the SN65DSI83 to detect the SoT preamble. The LP exit-to-HS transition of only 3.5–4 ns confirms that the LP-01/LP-00 states were either skipped or collapsed to a duration undetectable by the bridge's LP receiver. Without a valid SoT detection, the bridge will fail to synchronize to the incoming HS burst, causing the display to miss that video frame and produce visible flicker.